J4 ›› 2009, Vol. 44 ›› Issue (9): 22-27.

• Articles • Previous Articles     Next Articles

Crack fault diagnosis based on MEP and frequency contour lines

 LIU Meng-Jun, XIU Li-Meng, LI Jin-Bing-Bang-Chi-Yuan   

  1. 1. School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001,  Heilongjiang, China; 
    2. School of Information Science andEngineering, University of Jinan, Jinan 250022,  Shandong, Chioa
  • Received:2009-06-20 Online:2009-09-16 Published:2009-11-05

Abstract:

On the basis of a traditional evolutionary algorithm, a new method of crack fault diagnosis is discussed. The method uses the inherent frequencies as crack diagnostic parameters. According to the intersection point of frequency contour lines and the forecasted results of MEP, the structural crack position is located. The results show that the method can effectively integrate bothadvantages and achieve rapid and accurate location of the crack.

Key words: crack fault diagnosis; inherent frequency; multiexpressionprogramming (MEP); frequencies contour lines

CLC Number: 

  • TP206+.3
No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!